Val-matic Cam-Centric Plug Valve Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Val-matic Cam-Centric Plug Valve herunter. Val-Matic Cam-Centric Plug Valve User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 11
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Val-Matic
®
Cam-Centric
®
Plug Valve
Operation, Maintenance and
Installation Manual
INTRODUCTION ........................................ 2
RECEIVING AND STORAGE .................... 2
DESCRIPTION OF OPERATION ............... 2
VALVE CONSTRUCTION .......................... 3
INSTALLATION .......................................... 4
MAINTENANCE ......................................... 7
TROUBLESHOOTING ............................... 9
DISASSEMBLY .......................................... 9
REASSEMBLY ......................................... 10
PARTS & SERVICE ................................. 11
WARRANTY ............................................. 11
VALVE AND MANUFACTURING CORP.
905 Riverside Dr. Elmhurst, IL 60126
Phone (630) 941-7600 Fax (630) 941-8042
www.valmatic.com
Manual No.
CCPV-OM2-3
Seitenansicht 0
1 2 3 4 5 6 ... 10 11

Inhaltsverzeichnis

Seite 1 - Operation, Maintenance and

Val-Matic® Cam-Centric® Plug Valve Operation, Maintenance and Installation Manual INTRODUCTION ...

Seite 2 - DESCRIPTION OF OPERATION

SIZE TORQUE (FT-LBS) 1/2"-13 45 - 75 5/8"-11 100 - 150 3/4"-10 150 - 250 7/8"-9 200 - 350 1"-8

Seite 3 - VALVE CONSTRUCTION

PARTS AND SERVICE Parts and service are available from your local representative or the factory. Make note of the valve Size, Series No, and Serial

Seite 4 - INSTALLATION

2 CAUTION: Do not use valve for line testing at pressures higher than nameplate rating or leakage and damage to valve may occur. VAL-MATIC'S CAM

Seite 5

3 VALVE CONSTRUCTION The standard Cam-Centric® Plug Valve is constructed of rugged cast iron with a welded nickel seat and permanently lubricated bea

Seite 6

4 INSTALLATION The installation of the valve is important for its proper operation. The valve is capable of flow in either direction but the maximum

Seite 7

5 FLANGED ENDS: Flanged valves should be mated with flat-faced pipe flanges equipped with resilient gaskets. When ring gaskets are used, the bolt m

Seite 8

6 DIRECT NUT OPERATED VALVES: 8” and smaller valves may be equipped with a top-mounted nut for direct quarter-turn operation. The nut is 2” square

Seite 9

7 GEAR ACTUATOR ADJUSTMENT: The standard gear actuator is provided with factory-set open and closed position stops. If the valve does not shut off

Seite 10 - REASSEMBLY

8 PACKING REPLACEMENT: To replace the packing (7), it is recommended that the line be drained and the actuator removed. The valve can remain in the

Seite 11

9 WARNING: Open valve and drain line before removing cover bolts or pressure may be released causing injury. Place plug in lowest position before